- Flow Meters[10]
- Pressure Transmitters[10]
- Pressure Sensors[4]
- Instrument Parts & Accessories[7]
- Other Telecommunications Products[2]
- Testing Equipment[2]
- Integrated Circuits[2]
- Temperature Instruments[1]
- Electrical Contacts and Contact Materials[1]
- Other Measuring & Analysing Instruments[4]
- Power Distribution Equipment[2]
- Counters[1]
- Alarm[1]
- Contact Person : Ms. Hu Jessie
- Company Name : Nanjing Metran Measurement & Control Instrument Co., Ltd.
- Tel : 86-25-52366120
- Fax : 86-25-52899138
- Address : Jiangsu,Nanjing,No.12, Rungu Road, Guli Industrial Zone, Jiangning District, Nanjing
- Country/Region : China
- Zip : 211146
Thermocouple/duplex thermocouple/flexible thermocouple
Thermocouple/duplex thermocouple/flexible thermocouple
Normally, it isassembled with display instruments, recording instruments, computer, etc. It is direct used to measure site temperature of liquid, vapor, gas and solid surface with output 4-20mA.
Feature
Two-wire output 4-20mA, strong anti-jamming capability;
Save the costs of compensation wire and install temperature transmitter;
Safe, reliable, and long life;
Automatic compensation of cold junction temperature, non-linear correction circuit
Technical Parameters
Product performance standards
IEC584 IEC751 IEC1515 JB/T5518-91 JB/T7391-94
Temperature range and tolerance
1) thermal resistance
Model sub-degree temperature range, accuracy grade tolerances
SBWZ Pt100 -200 °C ~ +500 °C
Class A
Class B ± (0.15 +0.002 t)
± (0.30 +0.005 t)
SBWZ Cu50 Cu100 -50 °C ~ +100 °C --- ± (0.30 +0.006 t)
2) thermocouple
Model indexing Tolerance Level
Ⅰ Ⅱ
Tolerance value of the temperature range tolerance value of temperature range
SBWR K ± 1.5 °C -40 °C ~ +375 °C ± 2.5 °C -40 °C ~ +333 °C
± 0.004t 375 °C ~ 1000 °C ± 0.0075t 333 °C ~ 1200 °C
SBWR N ± 1.5 °C -40 °C ~ +375 °C ± 2.5 °C -40 °C ~ +333 °C
± 0.004t 375 °C ~ 1000 °C ± 0.0075t 333 °C ~ 1200 °C
SBWR E ± 1.5 °C -40 °C ~ +375 °C ± 2.5 °C -40 °C ~ +333 °C
± 0.004t 375 °C ~ 1000 °C ± 0.004t 333 °C ~ 900 °C
SBWR J ± 1.5 °C -40 °C ~ +375 °C ± 2.5 °C -40 °C ~ +333 °C
± 0.004t 375 °C ~ 1000 °C ± 0.004t 333 °C ~ 750 °C
SBWR T ± 0.5 °C -40 °C ~ +125 °C ± 1.5 °C -40 °C ~ +333 °C
± 0.004t 125 °C ~ 350 °C ± 0.0075t 333 °C ~ 350 °C
6, output Signal: 4-20 mA, load resistor 250, the transmission line resistance 100
7, Output Method: two-wire system
8, Accuracy:
Temperature Transmitter Accuracy class: 0.1 0.2 0.5
Display Accuracy class: 2.5 analog indication; figures show 0.5.
9, Power Supply: 24V.DC ± 10 %10, Protection: IP65
11, proof grade:
Flameproof: d Ⅱ BT4 d Ⅱ CT5 d Ⅱ CT6
Intrinsically Safe: ia Ⅱ CT6
12, the insulation resistance between the insulation resistance: meter output terminal and the shell should not be less than 50.
Thermocouple/duplex thermocouple/flexible thermocouple