Single-Channel and Detecting-Element Safety Barrier
Product Detailed
Related Categories:Electrical Contacts and Contact Materials
Safety Barrier
1.Intrinsic-safe and explosion-proof
2.Magnetic isolation technology
3.High anti-interference ability
MTA/DGA-1100/1200(ib) Single-Channel and Detecting-Element Safety Barrier
Functional Overview
MTA/DGA--1100/1200 single-channel and detecting-element safety barrier is a modular card loading intrinsic-safe explosion-proof instrument. It provides field two -wired transmitter with isolation power, restricts dangerous
energy entering into dangerous places, and transforms the 4-20mADC signal that comes from the field two -wired
transmitter into isolated 4-20mADC or 1-5VDC signal. ( Please refer to functional schematic diagram for details)
.
Technical Parameters
Input: 4-20mADC (signal that comes from the two-wired transmitter)Input Channel: OneSampling Resistance: 50ΩOutput: 4-20mADC Or 1-5VDC Distribution Voltage: 18.5-28.5 VDC (DGA-1200 without the power distribution)Output Resistance: 250Ω ( 1-5VDC output) >500kΩ(4-20mADC output)Load Resistance: ≤350Ω (4-20mADC output. Please note if you want special load resistance, 250-750Ω is available)Accuracy: ±0.2%Common-Mode Interference: when 50Hz, <5mV. Response Time: <1sZero Adjustment: ZERO potentiometer Measuring Range: SPAN potentiometer Power: 24VDC ±10%Power Consumption: <1.5WEnvironment Temperature: 0-50°CRelative Humidity: <90%RH(non-condensing)Insulation Resistance: the power, input, output terminals≥100MΩInsulation Intensity: the power, input, output terminals1000VDC/ minuteMaintenance: Instrument can carry electricity pluggable under the condition of installation wiringWeight: about 150gDimension: MTA: 29×106×72 (width×height×depth)mm DGA: 23×106×72 (width×height×depth)mmInstrument Installation: Standard 35mmDIN guiding rail card- loading installationSingle-Channel and Detecting-Element Safety Barrier